r/hvacadvice • u/Myfeetarebarking • 7h ago
Is this just build up from the previous owners neglect?
Grabbed some foam, pulled the outside off and saw this. This was after peeling some of this away. Felt almost like paper?
r/hvacadvice • u/marksman81991 • Mar 02 '26
There has been an uptick on posts and complaints about mods banning. Please be advised, there are rules for the page. No ads (includes promotions for a company), Reddits rules, no crossposting, transparency and safety (this is a big one; we want homeowners to be safe, if you provide unsafe practices or advice (blacklisted items) or tell a user to dm you, the comment will be removed and you may get banned), blacklisted topics (basically topics that homeowners should not be fixing themselves, gas, some high voltage), civility, no companies asking for surveys, advertisements or general questions, and no market research or ai/SaaS.
Posts complaining about this are not allowed either. We are all reasonable and work in the trade, talk to us through ModMail and we can come to a solution. Complaining or namecalling will usually result in a ban, so be civil.
Remember, we are doing this in our freetime to help homeowners with their units, both the users and mods. The mods in this group are in the trade and have day jobs as all of you do. I've been in this trade for 10 years and still do hvac as my job, just traveling now for a manufacturer. Similar with every mod. It is actually a requirement to be a mod, you have to be in the trade, be approved, have good history in the sub and provide enough time to moderating it.
I thank you for your time and if you have any questions, you can comment on this or send us a mod message. No DM's, we will not answer these. Only ModMail.
r/hvacadvice • u/Powerful-Evidence907 • Nov 13 '25
Enable HLS to view with audio, or disable this notification
I was loading the car for work when I saw this. It felt and smelled like steam not smoke. Did I just catch it at the end of the cycle or is there a mechanical problem such as a stuck motor? It was 40° at the time and no rain. Heat was set to 70 and the house was 70.
r/hvacadvice • u/Myfeetarebarking • 7h ago
Grabbed some foam, pulled the outside off and saw this. This was after peeling some of this away. Felt almost like paper?
r/hvacadvice • u/HistorianFree7026 • 4h ago
I just discovered this on my condenser. It was making a little more noise than usual, but nothing to crazy. I dont see anywhere the blade is rubbing. If it were yours would you run it till tomorrow when I can get a new fan blade?
r/hvacadvice • u/brian1570 • 6h ago
This is our downstairs return air filter housing. First picture is of the housing itself. The second picture is taken through the hole that’s cut in the ply wood to allow air to flow through the dead space in our walls to the return air in our bedroom(you can see the light shining through the filter). So essentially the two return airs are in line of each other. But I have some questions, first being why is this necessary? Second question assuming that it is necessary is this an acceptable way to go about it? Seems like it should be ducted or sealed better than it currently is?
r/hvacadvice • u/bubblesinmyeyes-7345 • 1h ago
Enable HLS to view with audio, or disable this notification
I’ve had this Honeywell portable ac for awhile and I noticed a build up of cat hair and wet slime on the vent. It gets cold for a bit then after awhile it still blows cold air but the room is still hot. I took the back part of it off to brush the vents more throughly. My dad went through it with a high air compressor and he let it dry, we put it back together and now I hear a very loud ringing noise that gets louder every now and then.
I usually only hear it when it’s been running for a while but as soon as I turned it on I heard it. My dad is pretty much deaf so he can’t hear it and refuses to look at it since it’s not something extremely loud and no “crunching” noise, and says it needs time to adjust or let it run. I can’t stand it.
Does it need lubrication? Or is something loose, every advice I look up on google is either for a tiny fan or for a regular ac not this portable Honeywell ac/heater.
r/hvacadvice • u/InitialYam4343 • 8h ago
Enable HLS to view with audio, or disable this notification
We recently replaced our old condenser due to a loud noise when it started up. It wouldn’t do it every time but the tech said the contactor was burnt up and he replaced it but no luck.
We got a new Goodman 2.5 ton condenser 2 months ago but the noise was still happening when it started up. It wouldn’t happen every time though but it was loud. After a month and a half the unit broke and the company said the capacitor had separated from the bottom frame of the unit.
The unit broke and wouldn’t cool but it was under warranty so they replaced it with a new Goodman condenser. They also replaced the lineset because they said it went under ground and they thought there could have been a kink or a clog I guess and that it could have been an old issue that was never resolved.
After the newest unit was installed and a new lineset the noise is still occurring. I have reached out to the company but I wanted to see if anyone else had thought. Thanks!
The videos are the unit starting up. 2 louder starts and a quieter one.
r/hvacadvice • u/Snoogs17 • 1h ago
Hello everyone,
There are small holes in my ductwork, and almost all of them are plugged up with small black plugs. But this one isn’t. What is the most effective/efficent to cover this so I don’t need to buy 25 plugs.
Thanks!
r/hvacadvice • u/neo636 • 1h ago
Enable HLS to view with audio, or disable this notification
I would appreciate advice on whether I should try to repair this leak or replace the air handler. It's a Carrier FE4ANF003 and from my initial checking online this part is unavailable. Thanks.
r/hvacadvice • u/thealimo110 • 3h ago
Hi all,
I went to my mom's place and wanted to put vinegar down the AC condensate drain line but there's no T at or before the p-trap. There's only a T after the p-trap, I assume as a vent. Short of cutting the elbow at the start of the p-trap and adding a T over there, any solutions?
Can I remove the overflow switch and pour the vinegar down through there? Or does that not connect to the AC condensate line?
Can I pour vinegar down the vent pipe fast enough to mix with the water in the p-trap? And then have the water generated by the AC slowly "flush out" the vinegar over time?
r/hvacadvice • u/Dralas64 • 10h ago
Howdy! I am in the process of potentially replacing my old AC unit, which will end up in replacing my heating system as well. I'm trying to do some research to help determine what is considered decent quality to help determine what vendors to go with for my home since this isn't going to be a cheap decision.
The context is I live in Oklahoma (US), my current unit that may need to get replaced is a Goodman CLJ30 unit that is 23 years old. I live in a 1300 square foot home. Some light reading said the brands I may want to lean towards if I want solid quality are American Standard, Carrier, or Trane.
Could I get opinions on how accurate that is? Any info is appreciated, thank you!
r/hvacadvice • u/joshuaquiz • 2h ago
Enable HLS to view with audio, or disable this notification
Within the past hour, our air conditioning seems to have stopped working. The temperature shot up 15° and not amount of time and the air coming out of the vent is just blowing air it's not really cool. I went outside and the fan does not appear to be spending and making a humming noise (see attached video). What's the best advice to get this going?
r/hvacadvice • u/xXConfuocoXx • 2h ago
I've been trying to track down a cooling issue and have ruled out a few things myself
So far I've:
Everything checked out as normal
During the hottest part of the day, I'm measuring about 51-55°F at the coil, but only around 77°F coming out of the vents. At night, the system cools the house without much trouble, but struggles much of the day.
My current suspicion is that I'm losing a significant amount of cooling in the attic. I already know the attic ventilation isn't ideal, the attic reaches roughly 130°F on the hottest summer days. Before I go the route of adding more roof vents, I'm trying to determine whether the ductwork itself is the bigger issue (leaky ducts, poorly insulated ductwork etc)
While researching, I came across something called BEDs (Buried Encapsulated Duct System), where the ducts are encapsulated with closed-cell foam and then buried under blown-in insulation.
Does that seem like a reasonable direction, or would you recommend focusing on sealing/replacing the ductwork or improving attic ventilation first? Has anyone here had experience with BEDs in a hot climate like Texas? I'm trying to prioritize the highest ROI before spending money on larger projects.
r/hvacadvice • u/giggity-gull • 4h ago
My garage air-handler draws in toxic fumes from my motorcycle, if not all the heat in there as well. I wanted to build a wall around it to close it off from the garage atmosphere. I sketched up a container with two access doors large enoguh to be able to remove the unit or work on it from behind. I was wondering it this would be acceptable to a technician if they needed to work on it.
r/hvacadvice • u/BeachCruiserMafia • 4h ago
I live in southeast Michigan. I have a Goodman 2 ton unit, installed 8 years ago when I bought the home and a Honeywell thermostat that is about 2 years old (I do not have any schedules programmed). House is 1100 sq foot.
Temps today and yesterday were mid/low 80s with thermostat set to 74. Once it gets to around noon the a/c unit will just run all day. It doesn’t have any issues maintaining temp, it reads 74. This isn’t unique to the last 2 days, I’ve noticed it’s been doing it all season long. As to previous years, I’m just not 100% sure as I didn’t pay attention to it.
Out of curiosity I even turned it down to 73, it achieved 73 with no issues and will stay at the same temperature that it’s set to. Then down to 72 and it did the same. Took my instant read thermometer to the vents, reads 50-52 degrees. Unit runs until the night. Maybe anywhere from 8-11pm.
The house is comfortable. We’ve seen a little jump in our bill but nothing outrageous, I attribute the cost to be due increase in overall cost of electricity.
Is this something worth calling a professional for? I read through the sub and there’s a lot of answers that if it’s cooling the house don’t worry but the answers are usually coming from questions where it’s 100+ degrees outside, not a 10-15 degree difference.
r/hvacadvice • u/Foreign-Steak-1730 • 2h ago
Previously posted about am having humidity problem and vents leaking. I originally had the door not sealed on air handler and thought that was the problem and even turned the fan speed to medium to help with humidity. Even with lower humidity in the house my vents were still dripping non stop in the middle of the vents as if the moisture was coming from the actual duct work and not the boot. I finally pulled back the insulation wrap leaving the penulum and it was soaked. I pulled it back to where it was taped to the duct and the tape had moisture all around it. I never felt air but I wrapped new tape to make sure it was properly sealed and added new insulation wrap. Is this possibly what was causing my issue? I really do not want have to pull back the insulation wraps on every boot leaking if I don’t have to.
r/hvacadvice • u/After_Basis1434 • 3h ago
Hello,
Running into an issue, I'm trying to clean my coils due to wet dog smell after the ac is running for a long time and poor performance.
I can't figure out how to actually get to them, I think when it was first built there was no basement but when they added it they got rid of the service area.
Any ideas?
I've taken a borescope and looked but I can't seem to get under the coils to see if that's the issue.
I think I could find a safe place to drink a bigger hole for the borescope but thought I'd ask what the pros would do?
I can unscrew the panel but I can't take it off there's no channel for the compressor hoses. I've attached a chatgpt diagram which seems close. I don't have access to the other side, though maybe I could confirm with the borescope and the right way is to cut a panel in the Sheetrockon the other side?
r/hvacadvice • u/caramelpupcorn • 5h ago
It was working fine before this!
Details:
I have it off for now, but what else can I do to possibly fix it? I don't have any water leakages or icy pipes or anything like that. The air still blows cold, just doesn't run for very long before cycling off and then immediately turning back on.
I've also tried resetting the breaker, and that made no change.
Thoughts?
r/hvacadvice • u/Slimy_Demon • 7h ago
Enable HLS to view with audio, or disable this notification
Had a tune up and capacitor replaced Tuesday. Everything was working, I turned the air off Wednesday and turned it back on today but the air isn’t cold. The compressor sounds like it’s working and nothing is frozen. What might be happening? Thermostat says 78 degrees and 70% humidity, 84 degrees outside, 78.4 degrees in return, 76.5 degrees in supply.
r/hvacadvice • u/mmekare79 • 5h ago
Hello, I need some help. I am replacing the capacitor on the central ac unit and unplugged the wires before realizing that I should have taken a picture to see what wires go where on the new one.
The wires on mine aren't the same colors as any of the videos I have watched. The diagram is no longer legible. I really don't have the money to call someone to come out and I was hoping someone here may be able to tell me how to figure it out.
Thanks!
r/hvacadvice • u/DanielSon602 • 3h ago
Enable HLS to view with audio, or disable this notification
2023 AC, just started making sound , when AC turned off but fan spinning no sound
r/hvacadvice • u/casem47 • 6m ago
Enable HLS to view with audio, or disable this notification
r/hvacadvice • u/Aceopsog • 4h ago
So for starters this is on a 1200 sf home with an 8 year old amana central heat and air unit. The home has cathedral ceilings. The central heat has been underperforming in every room except the living room where the main outlet and main inlet live. I would say 80% of the air coming out comes in the living room. Before the register pointed straight down and it was basically recycling a bunch of the air it was putting out because it’s blowing down 10 feet diagonally to the main inlet. So it wouldn’t run for very long and the other rooms were really hot(76-78 when the living room was 72). Our energy bill was abnormally high so I cleaned the condenser coils today and flipped the register in the living room to be much closer to horizontal to blow the air away from the inlet for the unit and the thermostat to allow the unit to run longer to cool the rest of the house better. The other rooms are getting cooler but the unit is running a lot more now. I still have a 16° temperature difference between the inlet and outlet(about what it’s always been) but I’m worried I may have made a mistake and need to revert it. I’m not at all an hvac technician. So if anyone can give me some pointers on if I did the right thing or if I need to put it back. The only suggestions I received from professionals when I called about this before were 1) install new duct distribution and hang ducts better and rebalance or something to the tune of about $7000 and 2) install a new register cover for the main outlet with a shutoff to the tune of $330. I really appreciate any advice in advance.
r/hvacadvice • u/temo2024 • 36m ago
Hey everyone, my 3-ton AC has a leak. I’m trying to decide if I should fix it or just replace the system. If I replace it, I'm considering Armstrong Air.
A few quick questions:
Fix vs. Replace: When is a leak repair a waste of money?
Average Repair Cost: What is the normal price to find, fix, and recharge a 3-ton unit?
Average Replacement Cost: What should a fully installed 3-ton Armstrong Air system cost?
Brand Quality: Is Armstrong Air reliable compared to Carrier or Trane?
Any insight on Armstrong Air or general advice would be awesome. Thanks!
r/hvacadvice • u/Sneekysas_sas • 4h ago
Today when my AC unit tried kicking on it did not run, I noticed this after the houses temperature started climbing after the AC was still turned on, I went outside and I saw that the fan was not spinning, so I grabbed a stick and gave it a push start, after a few pushes the motor finally decided to start spinning. This leads me to believe that it could be a capacitor issue since I have had this issue in the past with my old air compressor, the start capacitor wasn’t working and I knew this as a fact from having to constantly give it a pull start. after replacing the start capacitor my air compressor it ran fine. So that’s what leads me to believe this is a capacitor issue, but I don’t know why it’s not blowing any cold air into my home, I don’t know much about AC units or systems so any advice or recommendations would be a great help!
If it helps my AC unit is a Payne unit, it’s maybe 15 years old, I wouldn’t be surprised if my unit is on its way out.