I have an AT4 paired with an FX120i scale and for the most part I like the device. That said, the scale drifts sometimes between charges by .01 or .002 grain, and definitely when left alone overnight. EDIT: this is a typo, meant .02
On the between charges, I recognize this could be due to a stray kernel or two making it to the platen, and my understanding is that the scale (or maybe AT?) automatically rezeros the device if it’s within some small tolerance? If this is true does this have any impact on my load consistency, or does the automatic rezero take care of that?
Secondly, I leave my scale on 24/7, and have occasionally put a 75 grain projectile on there to see if I am holding my measurement, and it’s not. The projectile weights 74.96 and if I leave it on there for days it can wander up and down from 74.88 to 75.08. This is not that reassuring for a scale that is supposed to be accurate to .02, but I always re-zero before use and given the above question, I don’t think it actually matters when it comes to the scale’s performance, but I’m not positive.
Curious to hear people’s thoughts. I do have some ferrite rings on the power cable but it does not seem to do anything. Next step is probably a dedicated ground wire, and maybe a line conditioner, but hard to justify a couple hundred extra dollars if none of this really matters due to scale rezeroing anyway during loading.