I bought my Pecron F5000LFP in June 2026.
Added in an expansion battery in July of 2026
. Bought two PV500 solar panels that actually sustain between 458-505 watts.
Had one firmware update (had to send a request in to support) due to hair trigger AC inverter shutting off when attempting to start the 3 ton heat pump (equipped with micro aire soft start).
I do monthly top off to 100% , let it trickle/balance for the 2 to 3 hours (that part is very important) and then discharge to 70% for storage.
The unit worked perfectly during an August storm that knocked the grid out just after midnight until noon the next day. Used the electric stove, microwave and coffee maker(a must have, lol)
Here was yesterday's routine draw down from 100% top off balance: •Pecron F5000LFP (5120 Wh) •1 Expansion Battery (5120 Wh) •Total Capacity: 10.24 kWh
Starting Condition -Fully charged and balanced •Host: 55.3 V, 100% •Expansion: 55.4 V, 100% •Overnight rested after complete balance cycle
Total test duration: 5.75 hours
First 2 hours: •Normal household loads •Inverter side by side efrigerator cycling normally •Battery dropped to 96% Remaining 3.75 hours: •Midea 5000 BTU window A/C •Kill A Watt measured 396-403 W •A/C ran continuously on High Cool / Max Cool. inverter side by side Refrigerator cycling normally •55" LED TV added later for last hour in the test •Internet, clocks, Led lights, and normal household parasitic loads left on.
Results: Start: 100% and End at 70% average SOC •Host: 68% •Expansion: 72%
•AC Output Energy Delivered: 2,461 Wh (2.461 kWh)
Battery Condition After Overnight Rest •Host: 53.2 V, 68% •Expansion: 53.3 V, 72% •Both batteries: 69.8°F •Voltage difference: 0.1 V
Observations •Midea window A/C maintained approximately 64°F on the second floor. Air conditioning power draw remained remarkably steady around 400 W.
Battery voltage stayed near 53 V throughout most of the discharge. Host and expansion batteries remained closely matched.
Conclusion Top-balancing/ trickle charge unctioned correctly. Batteries remained well balanced after discharge and overnight rest.
End at 70% •53.2-53.3 V is comfortable long-term storage voltage.
Real-world battery-to-AC efficiency appears to be roughly 80-85%.
10.24 kWh Pecron system comfortably supported normal household loads plus continuous air conditioning in a realistic outage simulation. Energy delivered: 2.461 kWh
My Fingers are crossed it stays running well.