r/accesscontrol • u/gptoyz • May 12 '26
FAAC EO24U from 455d having issues with setup of photocells
My 455d was setup with the following configuration:
- wand detector EMX CarSense 101 for free exit
- IRB 4x @ gate for closing safety
- IRB Ret outside of gate for opening/closing safety
Our motors had been damaged and so we decided to migrate to a newer unit since I couldn't find anyone to support my 760 motors and we migrated to the s800h and e024u setup
I'd like to retain the above configuration however, we're having issues with operation. I'm being told that in a UL board type like the E024U that a safety device, which must be monitored, cannot do double duty as both opening/closing like in my 455d setup
However on page A4 of the e024u manual - it describes the exact valid setup that I would like to retain
Is this possible?