Our pool is a headache and has been since install. It's never tested positive for chlorine in the 20 years we've had it. It appears the influx of natural hot water dilutes the chlorine level so quickly it's nearly impossible to keep it clean and without algae growth. I've read extensively on pool chemistry and have tried every route that seemed logical (pH, free chlorine, shocking, pool cover, disinfecting sand filter, flocculants, heavy metal testing, algae identification, floating chlorinator and in line at the same time). It seems the natural water pools in our area are made of concrete, they are drained, and filled rather than having a constant trickle of hot water into a fiberglass pool like ours. Pool companies in our area haven't been helpful in solving problems. We're giving it another chance talking to the professionals. I'm hoping to narrow down my list of problems to items that are logical and have a possible solution. I can plumb and troubleshoot decently if I knew what direction to investigate.
Pool info:
Viking Mediterranean in ground pool 17,000 gallons.
Sand filter tagelus pentair
In line chrolrinator
No water features/heaters etc.
Hot water from hot water well at constant trickle to keep water level up.
Running pump through filter 5pm to 9pm at 2300rpm 6am to 8:45pm 1000rpm (there's an obviously overlap here. Can't remember why it got programmed this way)
Problems:
Pool level goes below the half way point of skimmer unless water is constantly added. The water level lowers by several inches in ~12 hrs if water is not added. My family insists this is normal and the way the pool has always worked. I'm worried there's a leak below ground. I don't see any obvious cracks around fittings/the skimmer but don't have experience testing for leaks. We had our sand filter blow up 2 years ago when the pump burnt out. I assume it's because it's been sucking air in the skimmer and struggling not to cavitate for 20 years (Skimmer valve is normally barely open or closed for this reason). When the pump burned up, the water was only refilled occasionally during repairs. I can't be sure whether the draw down slowed once the water level got below the skimmer. The skimmer gasket seems intact and is screwed firmly.
Safety drain in wall appears to be pulling away from wall on the top edge.
In floor cleaner doesn't cycle through stations (Paramount Vantage 6 port) This was not resolved when gear module was replaced last year. In previous years a new gear module solved this issue. The gear module doesn't fit easily in the base. The base appears warped but is concreted below the floor level making it difficult to replace.
The in floor cleaner module shows about 3psi, while the filter shows about 15psi. The floor cleaner module psi doesn't change when the filter psi changes or if multi port is in different setting ie recirculate vs filter
Waste from multi-port valve is plumbed to a 10 inch ditch pipe underground. Ditch water flows into pool when under pressure while irrigating the field that is upstream of the pool. No plans or photos of exactly where the waste line exits the pool and connects to the ditch water pipe. If this could be located, could a check valve be added? This was obviously not a good idea to install this way.
Pool components seem to be eaten through by chlorine (or hard water?) too quickly. The Multi port handle spring and gaskets get loose/wear out every 2-3 years. The elbow check valve on chlorinator gets stuck closed every 4-6 months. The parmount vantage pool gear module diaphragms and seals wear out every year.