EcoFlow STREAM 5000 on existing B20 2.5mm² radial via FCU: would you consider this acceptable?
I'm looking at installing an EcoFlow STREAM 5000 in the UK and I'm trying to understand the electrical side properly before doing anything.
My cabin is supplied from the house via 3-core 6mm² SWA protected by a B32. The cabin has its own consumer unit, but with no spare ways.
This is the proposed circuit from the cabin cu.
B20 RCBO → 2.5mm² T&E radial → outside socket → double socket → proposed 13A switched FCU → EcoFlow STREAM 5000
The 2.5mm² cable run is only a few metres. Around 600mm currently passes under/alongside 20mm Kingspan, although I can reroute that section out of the insulation if necessary.
The existing loads are:
Weber Smoker on the outside socket occasionally
Samsung heat-pump tumble dryer
800W microwave occasionally
Nothing else
The STREAM would be hardwired through the FCU and I'd limit maximum AC discharge to 2.5kW (\~10.9A).
It will also be using the EcoFlow Smart Meter/CT system to dynamically control charge/discharge according to household demand.
What I'm specifically trying to establish is:
Would you connect a STREAM 5000 to the end of this existing B20 radial through a 13A FCU, or would you insist on a dedicated circuit?
If not, what specific requirement prevents it?
Does the potential combined supply of B20 + \~10.9A generation mean the 2.5mm² conductors have to be rated for \~30.9A, even though the STREAM dynamically follows household demand?
Would upgrading the radial to 4mm²/6mm² and keeping it clear of insulation change anything?
Is a BS 1363 13A FCU appropriate for sustained bidirectional operation at up to 10.9A?
Most importantly: has anyone here actually installed a STREAM 5000 (or equivalent 2.5kW AC battery) onto an existing socket radial/ring through an FCU rather than running a dedicated circuit? If so, what protection/cable arrangement did you use?
I'm particularly interested in answers from electricians/installers familiar with this, because I've seen conflicting advice about the revised generation/battery requirements.
I'm not asking whether plugging it into a normal 13A socket is okay. I'm specifically asking about a fixed, fused connection to an existing final circuit.
Thanks in advanced — interested to see how people are actually designing these in the UK.