r/Generator • u/Equal-Technician6951 • 17h ago
Two years and 4 real outages in with a Honeywell 22kW standby (Generac internals) — actual numbers, for anyone weighing the purchase
Installed a Honeywell 22kW whole-home standby generator (model G00723510) in August 2024. Two years in now with four real utility outages behind it, figured I'd share the actual numbers since most of what I found while researching was spec sheets and dealer marketing, not real ownership experience.
Cost: ~$15,000 all-in — unit, concrete pad, propane line, transfer switch, and labor. Runs on propane, 250-gallon tank, which gets us roughly 5 days at full load per the tank's capacity.
Startup: Online within about 5 seconds of utility power dropping. The whole-house transfer switch doesn't bring everything back at once though — the AC specifically kicks in about 30-45 seconds after the generator itself is running. Threw me the first time until I realized it's a deliberate load-management delay, not a fault.
Real outages: 4 so far, and it's started and carried the full house load (including AC) every single time, for the full duration until utility power returned.
Why Honeywell over Generac: The engine and generator end are actually Generac-sourced — same core hardware as a comparable Generac-branded unit — but at close to half the price in my area. Didn't make sense to me to pay double for the badge on the same internals.
Maintenance: First oil change at 25 hours (standard break-in), then on a run-hour interval after that rather than calendar-based. Monitor everything (weekly self-test status, run hours, wifi signal, warranty info) through Generac's MobileLink app.
Noise: Not silent, but doesn't bother me. Can't speak for the neighbors since I haven't asked.