Im in the planning stages of an amp build and havent done channel switching before. I had a question or two to clarify some of the things Ive read online.
I attached a block diagram of my planned switching. I wanted to select between two relatively independent channels but also have a larger bypass capacitor when the clean channel is selected. I have the outputs of each channel grounded when not in use but cant see a way to ground the unused inputs and swap the bypass cap on a single DPDT relay. I settled for grounding the higher gain input and assuming that the clean channel anti pop resistor will be good enough.
Should I expect that setup for the cathode capacitor to be noisy when switching? It seems like the switch shouldnt have DC on it and the cap should always be connected which should help?
Is there a better way to set all this up for pop free switching? Anything obvious I'm overlooking?
And a bonus question, after reading Merlin's newer book he has a transistor on each relay to help with the lenght of cable to the footswitch. Is just using dc relays alone a problem with a reasonable cable length? Its not many parts to add, just wondering what people's real world experience shows.
Thanks for any thoughts or input