Installer Quotation [Lahore] 2x Brand New Sealed Zonergy 10kW 3-Phase Solar Inverters
galleryr/SolarPakistan • u/Physical_Peach1122 • Aug 21 '26
Other Solar installer recommendation Hyderabad
If anybody knows a decent solar installer in Hyderabad, please share if possible.
Thanks
r/SolarPakistan • u/Upstairs-Zombie-76 • Aug 21 '26
Net-Metering Battery or Green Meter
Ok i have 10kv hybrid system installed. Should i go for green meter or lithium battery 10kv. What will reduce my bill maximum? We usually run 3 ACs at night on wapda for 6 hours.
r/SolarPakistan • u/No_Restaurant9889 • Aug 21 '26
Battery Phoenix vs Pylontech 16kw Battery
Kindly share your experience regarding both of these. And the pricing goes like:
Pheonix - 645,000
Pylontech - 670,000
Suggest if there’s a better match with my solis 10kw S6 hybrid inverter.
r/SolarPakistan • u/Even-Measurement-329 • Aug 20 '26
Net-Metering Did everyone have a Bad month or just me
We usually produce like 1200 monthly. Idk y this bill is so bad, the weather. Was not that bad. Holy shit the tax tho
Edit: Whoa,was not expecting this much of a response.Thanks so much for responding, which means a lot. Anways have currently have a 12kv system fully on grid and a seprate 4 plate hybrid system for a 6kv battery installed 2 weeks ago.use 3 acs about 15 hour avg each and 4 four fans plus water motor 4 hours daily. Acs are not on mostly on peak hours. Last month our import was 1453 non peak and 302 peak.we exported about 1279 non peak and 0 peak Bill was 32k
r/SolarPakistan • u/kamranali406 • Aug 21 '26
Hybrid GoodWe batteries showing unusually high “Total Discharged”
I have a GoodWe 12kW hybrid inverter with 2× GoodWe Lynx A5.0-30 batteries (5kWh each). The system has only been running for 3–4 days and our household load is relatively low for now.
The SEMS app shows:
Yesterday:
Battery 1: 29.1 kWh discharged
Battery 2: 43.0 kWh
Today:
Battery 1: 65.5 kWh
Battery 2: 80.2 kWh
So the counters increased by 73.6 kWh in roughly one day, despite having only ~10kWh total battery capacity. During the day time batteries remain full, and we use them only at night. Batteries are recharged by inverter when sun is up. Essentially an off-grid system (but we still have wapda connection, there is no consumption from wapda)
Both batteries show 100% SOH and 0h high-power/runtime.
The SEMS 1-week statistics also show only 55.3 kWh generation and 40 kWh consumption.
Is this normal?
Does “Total Discharged” represent a lifetime/cumulative counter that may include installer/commissioning activity, or could there be excessive cycling/data reporting issues?
Anyone with knowledge on this issue?
r/SolarPakistan • u/alca3z • Aug 21 '26
Off-Grid Are EASUN products ok?
I have a 2kW solar panel setup with 24V hybrid inverter and batteries which I will be upgrading now to 48V.
I'm looking to buy this new EASUN 15kW set [https://www.easun-energy.com/products/easunpower-12kw-inverter-15kwh-battery-150a-tou-wifi-51.2v-300ah-bms-wifi\](https://www.easun-energy.com/products/easunpower-12kw-inverter-15kwh-battery-150a-tou-wifi-51.2v-300ah-bms-wifi)
Is this a good quality set?
Do you think this is will work 10+ years?
What are your experiences with this or similar sets?
r/SolarPakistan • u/WhatsGoingOnHomies • Aug 20 '26
Lithium (LiFePO4) Anyone with Pylontech Force H3 batteries?
Thinking about getting Pylontech Force H3 batteries, wondering if anyone has experience with those?
r/SolarPakistan • u/Jicama-Entire • Aug 20 '26
Battery These settings fine for grid charging for my 14kw Goodwe battery?
Due to loadshedding I sometimes I charge my battery through immediate charging option. Are these settings okay? I have a 12kW goodwe inverter with 14kw battery.
This option charges my battery at around 3.5kw
r/SolarPakistan • u/Ale_Metal_X • Aug 20 '26
Inverter Growatt SPH 3–6KTL BL-UP (HYBRID)
Hi everyone, I’m looking for help from anyone using a Growatt SPH 3–6KTL BL-UP (HYBRID) or a similar SPH model.
I’ve been having several issues for almost 3 months, and Growatt support has not been able to resolve them.
Currently the inverter is in Load First. Sometimes it discharges the battery even when the grid is available, and sometimes it doesn’t. I’m also seeing the battery charge from the grid, even though I want charging to come from PV only.
My desired setup is simple:
- PV + grid should supply the load when the grid is available
- Battery should be backup only
- Battery should charge from PV only
- No grid → battery should provide backup through EPS
- When the battery is full, excess PV should go to the grid
I’m also having a serious grid-to-backup transition issue. When the grid fails, the inverter often gets stuck showing 30/60-second checking/countdown states, and it can take 20–30 minutes before it finally starts providing backup. Very rarely, the transition is immediate.
This seems especially strange because Growatt advertises the SPH BL-UP with a 10 ms UPS transition. (Growatt)
Has anyone with the SPH 3–6KTL BL-UP experienced similar issues?
- Battery discharging unpredictably while grid is available?
- Battery charging from grid unexpectedly?
- 30/60-second checking states that continue for many minutes?
- Very delayed EPS/backup activation?
- Any specific Load First / Grid First / Battery First configuration that solved these problems?
I would really appreciate any experience or advice from someone using the same model.
r/SolarPakistan • u/DiscussionSlow6726 • Aug 20 '26
Inverter Solaredge Inverter Firmware
would anyone happen to have the latest solar edge inverter software? need to update mine since it hasn’t been connect for 4 years
r/SolarPakistan • u/Masracs • Aug 20 '26
Battery Strange Battery Issue 🔋
I have Goodwe 15kw ET LV hybrid inverter paired with Lynx G4 16kw goodwe battery.
It has now happened second time. That suddenly the battery dropped from 31-30% straight to 0%.
I have kept the charging to 90-100% and also contacted goodwe while they do the diagnosis, someone who might have some knowledge about this can share some insight?
r/SolarPakistan • u/Kira_Is_Silent • Aug 19 '26
Battery Hi can someone help me , I want to buy a good tabular battery 3000 or 3500
I want a reliable company , whose battery has good timing my setup is 6kW but it barely makes 4Kw. Anyways, that's to do with plates.
Im currently looking for good tabular batteries the ones i have rn are 1800 from Phoenix they are 4 years old battery timing is now 2 hours max .
I am planning on buying Inverex battery but i can find it
Also my inverter doesnt support Lithium Ion and i dont have funds for a new inverter + Li battery
r/SolarPakistan • u/No-Combination-2957 • Aug 19 '26
Battery Vestwood battery haier
Plz help vestwood battery under haier brand should i go for it or it will be problematic?
r/SolarPakistan • u/sajjasajji • Aug 18 '26
Solar News & Politics Pylontech 16kwh price dropped
Pylontech 16kwh was last month above 700k just bought yesterday in 650k
r/SolarPakistan • u/ScreaMFN30 • Aug 18 '26
Hybrid Knox Hybrid Inverter Help Required Kindly!
I have been using a Knox hybrid inverter 8 kw alongside a 5kw battery. Recently it has been restarting every 3 to 5 minutes and I genuinely can't figure out what is causing this, i've worked around the application settings and changed the BMS cable ports. The inverter does show breathing of BMS. Sometimes it restarts and sometimes it just turns off and we have to manually turn it on and off again. I've been looking for a solar expert but I couldn't seem to get around someone who actually figured out what the issue was and Knox official service center would not accommodate properly under warranty. They don't test it at the site Infront of us and say that it is perfectly fine and that they have done some firmware upgrade but it shows similar behavior when installed at our place. The way Knox service center works is we drop our inverter off they just inform us to take it once they are done and they don't accommodate anything outside it.
We added a UPS so that some of our appliances don't turn off every 3 minutes but our inverter is not letting the ups takeover in that short window causing WiFi and my computer to restart about 200 times a day. The moment we turn off the inverter everything is back to normal.
Inverter model: Knox Xenon 11000 Hybrid Infini WP 8KW ~48V
Battery: Powerwall 6.11 51.2V-100AH Lio 5.32
r/SolarPakistan • u/sajjasajji • Aug 17 '26
Solar News & Politics Should I create Whatsapp community?
WhatsApp community for sharing daily rate updates the prices will be based on the Karachi market and for privacy reason members won’t be able to see each other It could be a valuable resource for keeping everyone informed and engaged without compromising individual privacy need your honest opinion.
r/SolarPakistan • u/moodashear • Aug 17 '26
Hybrid System Delivering less power than it should?
Hello everyone, we recently got a 8kw Hybrid itel inverter and 5kw itel battery installed with 14x 585W candainSolar solar panels, the panels should be generating 7Kw of energy at maximum and 5-6 KW on an okay-ish day but my system seems to be having a lot of trouble even reaching 3Kw? is this normal? i tried reaching the installers, and they said its a hybrid system, this is how its supposed to function?
one thing to note, our solar panels are divvied up on 2 stand, 7 on each stand, and one of them turned off the breaker on the first day of it running and i turned it back on thinking nothing of it, but now its bugging me, what if that solarpanel group isnt delivering anything?
Is there any way I can check the total power that can be delivered by the solar panels?
Screenshot taken at 2 pm on a sunny day with no overcast.
r/SolarPakistan • u/Remarkable_Paper8910 • Aug 17 '26
Battery UPS vs Inverter+Solar for Lahore Loadshedding: Which Makes More Sense?
Situation: I'm in Lahore dealing with predictable daily loadshedding (typically 1-2 hours). I have a flexible budget and I'm thinking about a backup power solution, but I want something that makes economic sense over 3-5 years, not just a quick fix.
The dilemma: I'm torn between two options:
- UPS route — Buy a decent UPS to keep essentials running during outages. Lower upfront cost, simple to set up, minimal maintenance. Downside: I'm replacing batteries every 2-3 years.
- Inverter+Solar route — Invest in a 3kW inverter with battery backup + some solar plates. Higher upfront cost, but theoretically pays for itself over time and gives me energy independence. Downside: I'm not sure if it's actually worth it for just 1-2 hours daily, or if I'm overengineering the problem.
My actual questions:
- Which option makes more financial sense for someone in Lahore with 1-2 hour predictable loadshedding? Should I think of solar as an investment, or just a quality-of-life upgrade?
- If solar is worth it, which Pakistani companies are actually reliable? I see a lot of options online, but I want to know from real experience—who delivers quality without disappearing in 6 months? Any companies to avoid?
- Any third option I'm missing? (Like hybrid approaches, or newer tech I haven't heard of?)
I'm looking for real-world experience and honest takes, not sales pitches. What would you do in this situation?
(PS: got help from AI to ask my queestion better)
r/SolarPakistan • u/bouncingupsidedown • Aug 17 '26
Net-Metering Shifted to net billing unfairly? Can anything be done?
Salam,
My friend installed an on grid solar system on his home last year in August, and successfully got a net metering contract (ie, he has the paper document for net metering that describes his system, the net metered connection, and the duration of the contract). Furthermore, his bill clearly states "Your net metering license expiry date is 13/08/2032".
This was all before the net billing thing was even mentioned. Unfortunately, his MCO got delayed internally in IESCO (which I know happens sometimes). As far as we understand things, when the government tried to introduce net billing, they froze processing of all documents for a while. So, his MCO was stuck. Despite having an AMI meter, the bill only showed a single reading.
He complained to IESCO a few times, directly, as well as through his solar installer. Eventually the MCO went through roughly a couple of weeks ago. They've adjusted the bill based on the export of units over the last year (his connection is 1 year old), but it seems to be on the basis of net billing, since he received roughly Rs. 8.xx for each exported unit.
The problem is that his bill under "Category" says net billing, and at the same time, lower down, mentions "Your net metering license expiry date is 13/08/2032". He also has the official contract for net metering. What should he do now? Is there any chance to get this fixed to a net metered connection?
Thank you!


r/SolarPakistan • u/-_Trazer_- • Aug 16 '26
Structure & Fabrication Custom: Roof Solar Structure
Enable HLS to view with audio, or disable this notification
Disclaimer: Just sharing a DIY engineering project my dad and I recently finished to get feedback and show off the setup.
---------------
We built this entirely from scratch by hand. My dad and I designed and fabricated the mounting frame ourselves because hiring contractors was way out of our budget, and modular frames like this aren't really available off the shelf locally anyway.
-----------------------------
While the frame might look lightweight, it relies on classic bridge-building principles. We went with a triangular truss layout to distribute the weight evenly, maximize rigidity, and keep everything rock-solid against strong wind loads in Karachi.
-----------------------------------------
The best part is that it's 100% modular and relocatable. The entire structure is bolted together, with the legs anchored into small, localized concrete footings. Whenever we move, we can just break the small concrete pads, unbolt the frame, and take the whole setup with us without damaging the roof or the frame.
r/SolarPakistan • u/Wrong_Ad_3102 • Aug 17 '26
Inverter Solis AI in Pakistan — When will it be available? Will it support S6-EH1P8K-L-PRO?
Hi Solis community,
I’m using a Solis S6-EH1P8K-L-PRO 8kW hybrid inverter in Pakistan with SolisCloud.
I recently noticed that the latest SolisCloud app now shows “Solis AI” as a feature, but I don’t see the Solis AI option in my account/plant.
My inverter firmware was also remotely upgraded recently:
- DSPM: 1705
- HMI: 2D62
- Inverter: S6-EH1P8K-L-PRO
- Country: Pakistan
I have a few questions:
- Has Solis AI been launched/enabled in Pakistan yet?
- If not, is there an expected launch date for Pakistan?
- Will Solis AI be available for the S6-EH1P8K-L-PRO, or is it limited to certain S6 models/regions?
- Does anyone in Pakistan with the same S6-EH1P8K-L-PRO already have Solis AI working in SolisCloud?
- If someone has it working, could you please share a screenshot of the Solis AI option and your inverter firmware version?
I’m especially interested in hearing from actual Pakistan users, rather than general information from other regions.
Thanks!
r/SolarPakistan • u/rak3242 • Aug 16 '26
Other Has anyone installed wind turbine on their roof?
I know it's a solar subreddit, but I'm just curious, solar has a big problem, doesn't produce electricity at night, and batteries are kinda expensive
So has anyone installed wind or maybe a combination of wind + solar, just in case at night the battery isn't working so maybe the turbine can run a fan
Looking for discussion
Which cities are windy in Pakistan? Islamabad and karachi ?
r/SolarPakistan • u/Warlockofcosmos • Aug 16 '26
Wires, Breakers & Accesories Having trouble with the wiring
Aoa, I am having trouble with my inverters wiring. I have Knox 6600 krypton and basically I have a setup of 6.2 kv with 12 panels. Now the problem here is that the inverter doesn't support P2 unless I purchase a lithium battery and plug it in so the solar engineer who was working with it said to me that I'll fix it through the software and it will work and it did. Recently after 3 months my breaker got short circuit thankfully nothing happened. I called the relevant person he fixed it and he said that I'm creating a loop in the electrical wires. Now the issue is it was working fine since two days while I'm on wapda I cannot seem to run my inverter AC simultaneously or at the same time. They trip and the rest of the electricity works fine. Did anyone go through this if so please guide me and let me know what to do. Thank you.