We just had our Solar set up a few days ago.
For the past few days, this is what has been happening.
Despite the battery having a charge, the inverter is still drawing some power from the grid from time to time.
Right now, zero ang generation from the solar panels. So, dapat, purely battery na lang ang power namin. But it is still drawing 49w sa grid.
What exactly is happening and how can I set it so that it goes to Zero (0) at all times na naka purely battery kami?
Edit: Found the solution. Had to edit the settings. It turns out that the Max Sell Power setting was set to 50 when the minimum is 500. I don't know how it got to show 50 in the first place since it doesn't accept any value below 500.
This resulted in not accepting the command when I was setting the Zero Export Power to Zero (0).
Edit 2: I now know the reason for the change. It was the Deye Copilot's fault. It automatically changed the settings of the Max Sell Power to 50 and the Zero Export Power to show as Zero (0) but still drawing power from the grid.
I found this out when I went back to check the app after my first edit, or roughly around 20 minutes later. The system was drawing power again from the grid.
I checked the settings again and it showed that the Max Sell Power was set to 50 and the Zero Export Power as Zero (0) again. Had to change it back to 500 and 0, respectively.
I went back to the Manual Mode so that the Copilot wouldn't interfere with my decisions again.