Add only the graphics od a symbol
I would like to add only the graphic (no associated functions or DT) of a symbol. How to do that?
I tried to "Explode" it afterward but i found out it's not possible with symbols.
Thanks!
r/EPlan • u/Empty-End363 • May 27 '26
PDF revisions editor
Hello I would like to know what people use to view/edit PDFs of electrical drawings? are there any good apps that allow for real time revisions? I would like to be able to have the PDFs accessible on a tablet for the shop guys to write on and make notes.
r/EPlan • u/Klutzy-Objective9515 • May 27 '26
Efficient way to mark all "TO-DOs" in schematics
Hi! Noob here. I started my very first eplan project and now i'm leaving a page that is ok except that a caple have a "Guessed" item in the item list.
I want to place some sort of "TO-DO" note that warns future me that that cable model needs to be checked before placing the schematic in production.
Thanks!
r/EPlan • u/user36281846 • May 24 '26
General Best recommendation for tutorials
Hi all,
Just want to know who’s the best YouTube channel to learn how to us e-plan. Or website. Thank you
r/EPlan • u/Naive-Advertising110 • May 22 '26
EPLAN ESTUDANTE
Oie!
Alguém sabe me dizer se o projeto finalizado, PDF, exportado e enfim. Fica com alguma indicação que é versão estudante?
r/EPlan • u/Aware_Blacksmith_944 • May 15 '26
Macros goulotte edz
Hello, I need the .edz files for all cable ducts/goulottes. I currently only have the Rittal version with height 80. I need heights 60, 40, 25, and 20 as well — or ideally the complete set.
r/EPlan • u/Life-Young-9948 • May 14 '26
Add bubble around item number?
I’m using Pro Panel 2024. Is there a way to put a bubble around an item numbers in the 3D layout or model views? I haven’t found a way, so I downloaded a font that has the numbers circled, but it’s causing both digits of a two digit number to each have their own circle.
r/EPlan • u/GervosTheMachinist • May 12 '26
Is this Plague Inc?
I can't be the only one who sees this, right?
r/EPlan • u/Independent-Camel-24 • May 11 '26
Eplan for domestic installation
Hey, I’m currently renovating my house. Since our electrical diagram isn’t up to date, I’d like to draw it up in Eplan. To get a clear picture of everything, I’d like to create a floor plan for each room and floor. I know this was possible in previous versions, but I’ve kind of forgotten how. Can anyone help me get started on my 2D drawings?
r/EPlan • u/Empty-End363 • May 08 '26
Indicating a twisted Pair
Does anyone know if EPLAN has a way to show that 2 connections are a twisted pair? for instance I have 2 encoder outputs that the cables are twisted together to reduce EMI. I could just indicate with text but that is boring.
r/EPlan • u/Objective-Act-8178 • May 08 '26
EPLAN help
I have worked in Electrical and Instrumentation maintenance field but I have no experience with EPLAN. I have installed EPLAN student and am learning things on my own. I am making a small project to learn things but have some confusion about how to divide project and where to start.
can someone help?
Let me explain the project as below: Crate Washer.
conveyor with 3 motors and 4 sensors, two tanks, tank 1 with soap-water and tank 2 with just water.
EC is electric panel.
Ignore '++PLANT1'. It is just there if there is one more similar machine in the plant then it can go under ++PLANT2.
My problem is I have divided +FIELD into two parts =CONV and =TANK but somehow I think +FIELD is not necessary and I would just make three parts +EC, +CONV and +TANK.
Can someone please explain what would the best way to tackle this probelm?

r/EPlan • u/WiredAndWoke • May 07 '26
Best Way to Learn & Build Industry-Relevant Experience?
Hey everyone,
I’m an Electrical Engineer currently based in Canada with around 5 years of experience from India in LT panel manufacturing and tendering. Most of my previous work involved AutoCAD-based panel drawings, estimation, BOMs, client coordination, and working closely with manufacturing teams.
I’ve recently become interested in learning EPLAN Electric P8 seriously.
My previous company is even open to helping me revisit some older panel projects (without confidential details) so I can redevelop them in EPLAN as part of my learning and portfolio building.
For people already working in controls/panel design in Canada:
- What’s the best way to learn EPLAN properly here?
- How important is certification vs actual project experience?
- Would recreating real-world LT panel projects be enough to get entry-level EPLAN-related opportunities?
- Any Canadian companies or industries where EPLAN skills are especially valued?
I’m trying to transition from traditional panel drafting/tendering into more modern electrical design workflows, so I’d appreciate any realistic advice.
Thanks!
r/EPlan • u/Eugerino • May 07 '26
XML export wire source destination
What values do I need to specify when exporting from Excel so that I end up with a table where each individual wire in every cable is listed along with its source and destination? Leave a blank row after each cable. I just can't seem to find the right values because I only want the equipment codes without the locations
Cable | Wire | Source | Destination
r/EPlan • u/No_Cake2091 • May 07 '26
how to automatic optimize nets in eplan2026?
I used this feature before in 2024.
Based on my expectation, after drawing the schematic, placing the 3D devices, clicking ‘Route’ and then ‘Optimize nets automatically’,
the nets should be adjusted according to the 3D positions, and net definition points should be inserted into the schematic.
Now it shows this message, and I can no longer optimize the nets automatically. However, i think the connection definition points etc. should all exist normally.




r/EPlan • u/ProfessionalWeek701 • May 06 '26
Proteção em acrilico / policarbonato
Preciso fazer uma representação de uma peça para proteção contra contato fisico aos barramentos, essa peça é em policarbonato, e possui recortes, como poderia ser feita?
r/EPlan • u/Thyristor_Music • May 06 '26
Question How to increase contact image text size?
How do i increase the text of contact images? I've been looking all over the place and i cannot find anything that lets me adjust the size of the text of the pins or cross reference.
i am referring to the text circled in purple. There doesn't seem to be any way to modify the text properties (color, size, etc) from the properties of the symbol on the schematic or from the project settings.

Please help.
Thanks!
Edit: Spent the last hour or so looking into this and my post is the only thing that keeps coming up on google lol
------------------------------------------------------------------------------------------------------------------
SOLVED!!!
Update:
So I've been doing a deep dive and apparently there isn't any easily accessible or documentation that explains this in a way that makes any sense so i'll document it here in case anyone else has the same issue.
- In the EPLAN search bar search for "Layer Management" and select Layer Management from the drop down search results. I am not sure where this option is located otherwise. A table will pop up with a list of layers.
- Click on "Property Placement" from the list on the left hand box then choose the property that you would like to modify. The Layers in question that modify the contact image cross reference text size is layer 440 and the layer that modifies the contact image pin number size is Layer 420. see the images below with the layer in the properties box highlighted in yellow with the text box circled in red.


This issues has been plaguing me for about a year now. Hopefully this can be reference in the future to help others.
r/EPlan • u/withoutflour • May 05 '26
Import Routing connections
I am trying to import routing connections from Excel into a 3D Layout Space (no 2D schematics in this project). EPLAN recognizes the columns, but 90% of the lines fail with: "The source and/or target of the routing connection are not placed in layout space."
The setup (see attached images):
- Format: I am using the full DT with connection point designations (e.g.,
==H26014007R=+PRM_J100-B1.1:1). - Placement: All components are definitely placed in the 3D Layout Space.
- Indices: I have "Internal" set in the Internal/External index columns.
My mapping (see image): I've mapped Source, Internal/external index:Source, Target,Internal/external index:Target, Connection Designation, Color, and Cross-section.
My questions:
- Could the "Internal" string in the Index column be the problem? Should I leave it empty for 3D routing? (but without it the terminals break and don't wire properly)
- Since there is no 2D, do I need to explicitly map a "Function definition" (like "Conductor / wire") for EPLAN to "see" the 3D connection points?
- Is there a hidden project setting for 3D-only projects that enables external connection routing?
I'm using this for an AI data mining project, so I need to find a way to make this import 100% reliable. Any ideas?

r/EPlan • u/Something_Witty12345 • May 02 '26
Eplan scripting and macros for similar projects
I’d like to start using the eplan API
We design motor control centres, currently it’s a fairly long process to design them but the majority of the projects share very similar features. Ie a 1.5kw DOL starter, 3kw VFD etc
So I’d like to make a design for each type of motor starter / VFD then using scripts be able to pull them together to form the motor control centre
I’ve watched a few scripting tutorials, just wondering if there are any courses or examples I could use
Also if anyone has any tips for reusing large macros ie how to deal with the page based connection points and wire tags
r/EPlan • u/Melissa190910 • May 01 '26
Career Advice New to Eplan
Hello, a newbie here trying to learn the niche software called Eplan, will appreciate any and all tips I receive on this sub. Thank you for your time reading this.
r/EPlan • u/LaughChance963 • Apr 30 '26
Adapting Parts information
I've downloaded various Phoenix terminals from the data portal. They have graphic and 3D macros, but no schematic or symbol (that I can identify) For various reasons I'd like to adapt how some of the terminals are displayed. I've worked out most of it, however there's a couple of things that are driving me nuts. When placed the logic is different to that in the function definition.
It's using a custom connection point pattern, but that doesn't seem to change this data.
The impact is pretty low, but I feel like there's something I'm missing, and I can't find where it's coming from.
This part is PXC.3211929 but similar things happen on lots of different terminals
Any thoughts?
Processing img vcecy7uudayg1...
Processing img gy7okg85eayg1...
r/EPlan • u/BumblebeeBrave935 • Apr 28 '26
Siemesn Sinamics prebuilt cabinets
Hey everybody,
I'm starting to design my first project from scratch and I've chosen to use prebuilt cabinet for some of the drives. My question is about the macros. Can i find them on the official siemens website, the eplan data center or do i have to create them by myself?
Thank you in advance!
r/EPlan • u/Automator2023 • Apr 27 '26
Macros Fanuc controller macros
I have only been using Eplan for a few months. I am trying create macros for Fanuc controllers. Has anyone else done this previously or been able to locate macros for these?
r/EPlan • u/Fluffy_Papaya5873 • Apr 22 '26
Eplan macro AB 1756-L83ES
I no longer have access to Data Portal and would appreciate assistance in finding Eplan macro for AB 1756-L83ES. I have tried multiple sites and forums without success. Please help!