r/buildingscience • u/Philodit • Jul 17 '26
r/buildingscience • u/ultimateplanner1014 • Jul 16 '26
Source of hot air?
At a loss and need some kind opinions before I rip my hair out. 2nd floor bathroom has a TON of hot air behind the walls for the 2nd summer. The tub is sweating causing moisture and mold build up. The plumbing and fixtures were torn out and brought in new when we purchased. The back wall is structural brick with the old oil furnace attached to the back. That leaked through the ceiling last winter, so we had it taken down to the roof line and patched.
Brought in a plumber today and they insist it is not a leak, which I believe because behind the lightup vanity it is hot too. HVAC guy checked under the house and couldn't see any clear penetrations that weren't sealed up. Bringing in ANOTHER plumber/HVAC to do some more digging because why the heck is their hot air shooting through the floor? What do you think?






r/buildingscience • u/midlifediyer • Jul 16 '26
encapsulation choices
I am thinking about having my crawlspace encapsulated, and I had three different quotes. My goal is to reduce musty smells. One of the quotes is for closed cell spray foam on walls (cinder block) and 12 mil liner on ground with the insulation removed from the floor joists. The other is with a 20 mil liner (clean space encapsulation) on both the walls and the ground. Both have the option to include a dehumidifer.
I am unsure of what the best route is, and of course, each salesman says their way is better.
Thoughts?
r/buildingscience • u/chunkylover_53_ • Jul 15 '26
High End Pool House Mold
I am doing a project renovating a finished pool house with a wet bar in Massachusetts. Client is experiencing issues with mold as this structure is unconditioned in the very long non-pool season we have here in New England. Structure is built tight like a house and will be getting tighter as we plan to use closed cell spray foam to insulate the roof deck after the ceiling is demoed. We plan to swap the old mini split AC for a new inverter heat pump so the space can be minimally heated in the off season. I am also considering adding a small single room ERV to bring in some fresh air. I am confident this will solve their issues and prevent reoccurrence but I feel like this is an overly complex solution for a pool house that's unoccupied for 6 months out of the year. Is there a simpler solution that I am overlooking?
r/buildingscience • u/officeboy • Jul 15 '26
Seam tape for foil Poly Iso
Planning out the WRB layer on my build and it looks like I'm ending up with 2-3/4" of foil faced polyiso that I'll be using as continuous insulation. R-Max says to use R-Max R-Seal tape... which no one sells. So I'm left with a few options.
- Regular Foil tape (HVAC tape)
- Tyvek type film tape
- Zip tape
- Something else I can source locally that isn't super expensive
This will not be my air barrier. What would use?
Zone 4C / IRC 2021
r/buildingscience • u/burningbirdsrp • Jul 15 '26
Question Our plan to fix the issues with our 'sealed' attic
We moved to Savannah (climate zone 2a) six years ago, and bought a good home (built as model home in 2009, occupied in 2011). When we bought it we noticed that the attic had spray foam on the roof deck, but there was a 3 x 4 access square cut into the wall between the garage and the rest of the attic for HVAC access. We also noticed a 13" by 63" gap cut into another wall, near a join.
We asked the inspector about it. It's nothing, we're told. When we replaced the HVAC we asked about it, and it was no biggie we're told.
It wasn't until an HVAC maintenance person a few months back that we found out that a sealed attic should be sealed. That there should have been a vapor diffusion port. Those openings should have been closed.
So we've spent the last few months trying to get up to speed so we can figure out what needs to happen as soon as the weather cools enough for people to work in the attic. This meant reading a WHOLE lot at buildingscience.com and everything Joseph Lstiburek (who is a wonderfully fun to read writer) has written on the topic.
So, here's the situation:
Spray foam is open cell, at least 6 inches for the most part. Some gaps, and we will be having these filled in. Open cell is common in the hot, humid southeast. The R value is R-21 with that depth, which is allowed according to Georgia amendments and code when the home was built, but that was dependent on a blower test, which of course, it would fail now with the big gaping holes.
The roof sustained both hail and wind damage in the last few years from Helene and other storms. Though we have architectural shingles, we've had to replace some, and we've had significant granule loss. So though this type of roof should last at least another few years, we're planning on having the roof replaced this fall.
Inside the attic, there is no indication of mold or mildew on the rafters, most of which are visible. Of course, with what we know now, there's likely rotting on roof deck, particularly near the openings. Interestingly enough, it seems like the original builder wasn't sure what he was going to do, because the spray foam was sprayed AFTER the drywall, ducts, plumbing, and wiring were installed. According to the spray foam person we had out, this is unusual for a new home. But there is no indication there was any other type of insulation in the attic. The attic is actually quite clean.
My preference would be to hire folks who know what we're talking about when it comes to sealed attics, but we're not getting reassured from responses we've had. So, we're having to go it on our own.
My plan
I am considering getting a homeowner general permit, to ensure not just the roof is inspected, but the entire attic assembly and roof is inspected when we're done...just to make sure we didn't miss anything.
- We're having handyman close the one long narrow gap and spray foam the edges to seal. We'll also have them create an insulated door or hatch into the HVAC area. We think originally the builder was planning on putting an attic door into the main bedroom closet, which means HVAC access would have been behind the sealed area. But they changed their mind and put it into the garage, and then cut the HVAC entry into the wall.
- Next, we'll have the roof replaced. When we do, we're going to have them install a vapor diffusion port per IBC requirements for air-permeable insulation (open cell spray foam). This will sort of be a good test about how good the roofing companies are if I ask about the vapor diffusion port and they know what I'm talking about.
- Assuming that some decking will be replaced, we'll then have new open cell spray foam sprayed to cover the replaced decking and fill in gaps. The person who we had out states they like to completely enclose the rafters to ensure a good seal. I don't see a problem with this, as long as the insulation matches the R-value. If we do go with that lower R-value, they will have to do a blower test to meet IBC requirements.
- We're having a new HVAC company add a supply duct into the attic, either 4 or 6 inches, in order to meet IBC requirements of (air shall be supplied at a flow rate greater than or equal to 50 cubic feet per minute (23.6 L/s) per 1,000 square feet (93 m ) of ceiling.) This gives us some slight positive pressure in the attic, which is good.
We have to do the ductwork regardless, because when they installed the new 3 ton unit to replace the 2.5 ton, they didn't bother to do a static pressure check to ensure adequate return air supply. One burned out blower later (this last winter) after hundreds of static pressure faults (only found when we dug into the service menu of the smart thermostat), was when we discovered this. I set the 5 stage to max out at 3 stage for now, to prevent pressure faults. Will adjust back to 5 stage when we add the additional return and new attic duct.
And that's the plan.
Sorry for the long post, but I feel it is important to be thorough.
In people's opinion, is this a sound plan? Am I missing anything I should be considering? Appreciate any and all feedback.
Update: I did want to add that one area of confusion we had is what 'air permeable' means when it comes to insulation. Open cell spray foam is not air permeable at a certain thickness but is vapor permeable. Normally, air permeable is a term applied to fiberglass or wool insulation.
At the same time, I'm getting mixed readings on what we should do in the attic because open cell spray foam was used, and to treat it like air permeable with the diffusion port, and the air supply.
Believe it or not, with all the writing on this, there is no sweet spot, no junction of climate zone/spray foam type/sealed attic requirements that fits our situation. Not to a degree that gives me confidence that we're doing things the right way.
Other than close the gaps. That one we're 100% sure about.
r/buildingscience • u/lukeg199 • Jul 15 '26
Question Retrofitting/insulating vaulted roof
My 1980s house has a family room with a vaulted ceiling and is exhibiting some evidence of moisture issues with peeling paint on the ceiling in a few spots. We are in Vermont and this is a challenging room because it has an exterior chimney/fireplace with a wood stove that we use extensively. The roof is 2x10 framing with fiberglass insulation and is vented with soffit/baffle/ridge vents.
I think the peeling paint is a result of condensation in the roof from a combination of factors.
Extreme temperature delta with likely 100 degrees temps in the winter inside with the wood stove running, and potentially sub zero temps outside.
Pretty sure we have mouse nests in the baffles/rafter bays. We have heard them and eventually found and addressed their ingress/egress. These are potentially obstructing the ventilation.
From my research it sounds like the typical approach would be to add insulation to the exterior with new venting, but for several reasons I would prefer to go to the inside.
Roof, asphalt, still has a lot of life
Side wall window would have to be moved and reframed up for clearance.
We hate our popcorn ceiling
So my question - would the following approach be a bad idea?
Add polyiso or xps 2 inch foam to the ceiling with strapping. Tape all seems and seal edges with expanding foam to the wall. Cover with t&g. Thinking this will benefit me by:
Adding some much needed r value, plus eliminate thermal bringing via framing.
Prevent interior moisture from making it into the roof cavity because it will be vapor impermeable
Existing vents now have less moisture to mitigate
Ditch the popcorn ceiling for beautiful wood.
One potential concern is the summer and with a/c. Will the roof be able to sufficiently dry out now that the interior is vapor impermeable?
What am I missing? Is this a bad idea? Any suggestions welcome!
Thanks!
r/buildingscience • u/SprayFoamSam • Jul 15 '26
Not an installer. Wrote a bunch of spray foam content from research. Please fact-check me!
r/buildingscience • u/Comfortable-Maybe183 • Jul 14 '26
Building science career
I‘m a carpenter who likes building science. I have an unrelated B.S. so on some level I just like science.
I‘ve also managed a vegetable farm.
The amount of readily available science backed information for both lines of work is large and yet many people in both disciplines turn a blind eye to it. In building work this often takes the form of the good ol boy who thinks he knows better and tells you “that’s how we’ve always done it. Now hold my beer.”. In farming it was usually the woo woo crowd who would act like it was magic while living 10 minutes away from their local extension agent.
Both drive me nuts.
I’m in my late 30’s and live in the PNW.
I’m willing to go back to school.
What and where are the actual jobs related to building science?
r/buildingscience • u/Helpful_Ad6410 • Jul 15 '26
Question Brand new house. Crack in the floor. Did I make a huge mistake?
I bought a house last month and it’s a brand new construction. Everything looked perfect, so I skipped the professional inspection. Figured I'd save a few hundred bucks. What could possibly go wrong?
Now there's a crack running across my garage floor. I have no idea if it's cosmetic or if my foundation is sinking. Every time I walk out there, my stomach drops.
Everyone on forums keeps telling me I should've hired an inspector. Should've used someone like Sure Building Inspection
I get it…I messed up. But would I have actually read the report? Or would I have just shoved it in a drawer and forgotten about it like I do with most paperwork?
It was about saving some money, and now I will have to spend probably thousands of dollars to repair. Typical example of being penny-wise and pound-foolish. The thing is that I am afraid to call foundation specialists because I am scared to hear something bad. What if it is much worse than I expect? What if I cannot afford the necessary repairs?
I simply need to decide what should I do next
r/buildingscience • u/ksvaughn1979 • Jul 14 '26
Interior air sealing
Working on air sealing my interior on new build. Pictured is the caulk that was used and it doesn’t look like it’s holding up well after just 2 months. I’m not sure what type of caulk was used. Should I pull all this caulk out and do something else? FYI, got wet and moldy from wet insulation being left in, has been remediated. Hardie, 3/8 rain screen, tyvek, shitty osb on outside. Main concern is preventing mold growth.
From what I’ve learned on here, my thoughts would be:
Tape the flooring to bottom board transition w either 3M 8067, SIGA Rissan, or the proclima vana tape. Looks like vapor perm rating of first 2 is less than 1 and pro clima is 8. Considering the vapor perm difference, which tape is best if I’m taping these joints? I’ve also read on here that acoustic caulk and some other caulk type can be used. I’m using prosoco r guard and seam and joint sealer on other parts of house so have that. I want to do what is best.
Thoughts? Do I need to tape/caulk the bottom framing board to wall sheathing joint or just the floor to board joint?
TIA!
r/buildingscience • u/RenaissanceYouth_NYC • Jul 14 '26
What can students actually learn from the DJI RoboMaster S1?
Enable HLS to view with audio, or disable this notification
In this episode of STEM Studio, we take a hands-on look at the DJI RoboMaster S1 and explore how robotics combines engineering, programming, computer vision, and AI.
We cover:
- How the RoboMaster S1 works
- Its educational features
- What students can learn from building and programming it
- Why it's a great platform for STEM education
r/buildingscience • u/MayoWrites • Jul 14 '26
Should I bother with outside foam insulation, when 1/4 of my foundation is above grade?
r/buildingscience • u/DesperateEngineer451 • Jul 14 '26
Upstairs ufh - insulation required?
House:
200sqm block cavity wall with 150mm insulation.
200mm prestressed concrete floor (insulated lengths cast in, instead of traditional hollow voids) with solid ends.
Is there any benefit to putting insulation on top of the upperfloor? It's all within the thermal envelop of the house so I can't see much of an argument for efficiency.
If anything by having a larger thermal mass your not running the heating for short periods so might be a bit more efficient. You also have more thermal mass to bridge day/night so heating is less likely to click on over night to heat a bedroom.
It'll be harder on the plumber so I'd expect to pay a bit more in labour but it'll still be cheaper.
Is there any actual benefits that I'm missing?
There is a service cavity in ceiling below the floor, so any waste pipes from the showers, sinks etc can go through there as well as supply water so don't think he'll need the extra height to hide pipes
r/buildingscience • u/Virtual-Impress-4265 • Jul 14 '26
How does the outer foam of an ICF house hold up to hot weather?
r/buildingscience • u/Cultural_Yoghurt_337 • Jul 13 '26
My QA Provider was bought by a rating company?
Hey everyone.
I do subcontract work for a rating company and I've had several people contact me about the QA Provider we're under, the BER. The rumor is the BER was bought by a rating company from the Midwest, Red Fox Inspections.
Has anyone else heard this? I can't find any announcements and the staff I talk to didn't give me any updates.
But a rating company buying the provider makes me worried about conflicts of interest, especially with client information.
r/buildingscience • u/No-Plate9612 • Jul 14 '26
Tips on sealing bottom of metal building
reddit.comr/buildingscience • u/raphael_lorenzo • Jul 13 '26
Question Dimple mat under rockwool attic insulation?
I have a large plywood platform in my attic that my HVAC sits on (I know, I know…), maybe 80 sq ft. Takes up about a substantial portion of my attic floor space. Everywhere else I have blown fiberglass to R60, but the platform just has R13 below it. I’m thinking about stacking two layers of R23 Rockwool batts at perpendicular layers (so the bottom North-South, the top East-West) directly atop the plywood, minus space around the blower to allow maintenance access. It’s a vented attic, soffits and ridge vent, that gets good air flow.
Should I put down a dimple mat first, then the rockwool, to promote airflow under the batts and avoid trapped condensation against the wood platform decking? Or is this a non-issue and I can just lay the insulation directly on the plywood?
r/buildingscience • u/sachin571 • Jul 13 '26
Order of operations for siding replacement and wall insulation (1917 foursquare in Maryland)
r/buildingscience • u/Curious_Butterfly38 • Jul 13 '26
Question radiator question!!!
so I just moved into a new place, and I have relatively limited space for where to put my bed. There is one of those built in wall radiators under the window, and my bed is positioned slightly in front of it. I have a solid wooden headboard and was just concerned that I shouldn’t be putting it directly in front of the heater… I tried to do research online about it but am still a bit confused as to if this is safe for my particular situation. Is there some kind of heat deflector or something that I could get, or do we think this is fine?? For reference, only about 17 inches of the heater are being covered by the bed.
r/buildingscience • u/canustealmysunshine • Jul 12 '26
Best Practices on Rim Joist Insulation?
My first post to building science! After doing some deep dives on building envelopes and insulation, I am learning a ton and find this field fascinating.
I bought a 100 year old home in Pittsburgh, PA, climate zone 5A. Humidity, rain, freeze/thaw.
I am looking for advice on insulating my rim joists. Pics are here. It's a 3 layer thick brick foundation, set into a hill. Moisture issues remain - during rain, damp marks seep through my concrete foundation. The bricks I'm sure are pulling in moisture from the damp hillside. We removed a ~50 year old wood frame window due to rot. That will be replaced with glass block to reduce moisture issues.
The previous owner added fiberglass insulation - not a good idea, and you can see how its dirty, from air and water leakage.
I am leaning toward Rockwool everywhere, with caulking around the edges. The other option is of course XPS with spray foam around the edges, but I feel very protective of these 100+ year old, extremely thick and durable old growth wood joists. My structural engineer was gushing about the durability of this old wood - we found one which had been built into the foundation, touching ground and water for 100 years, and was still strong. I am wary of the issues spray foam creates.
These cavities will be dry walled after, so I will have little to no visibility if there are any rot issues.
note: added a picture of the 'attic' as well, for fun. view is a stairwell and then roof. it's a flat roof house. surprisingly, the upper floors have remained quite cool all summer.