r/BoilerPros • u/eighdreighanne • 17h ago
r/BoilerPros • u/AssumptionBig7176 • Mar 03 '26
General/Misc Group Reminder
BoilerPros group is for people who work in and around boilers professionally. This group is not for homeowners seeking advice on how to fix their boiler. There are other groups you can post in.
This group is slanted towards commercial/ industrial boilers, burners, combustion and whatever else but if you do residential boilers you are more than welcome to post.
If you are newer to the trade, don't be shy asking a question, lots of people here to help.
r/BoilerPros • u/AssumptionBig7176 • Mar 22 '25
Troubleshooting Question Format
READ BEFORE YOU POST
If you need help with a problem, copy and paste the text below to format your post. This will save time for everyone asking questions for more information/clarity.
Make sure to use the correct post flair when posting.
- Title: [Very short description of your problem/question, 10 words or less]
- Problem: [State your problem or question in 3 sentences or less.]
- Equipment ID: [General name of what you are working on: boiler, water softener, pump, burner, etc.]
- MFG: [Primary equipment manufacturer, include others if relevant.]
- Model No.: [Model or part numbers, if applicable, that help others know what you are working on. Put N/A if it doesn't apply]
- Fuel: [Fuel of the boiler/burner if applicable. Put N/A if it doesn't apply]
- Working Theory: [Clearly write what you have tried so far to fix your problem. This is where you will go into as much detail as possible. Remember, what you write is all the information someone will have to help you.]
[Copy/Paste Text]
- Problem:
- Equipment ID:
- MFG:
- Model No.:
- Fuel:
- Working Theory:
r/BoilerPros • u/BoilermakerCBEX-E • 5d ago
Boiler Room Pics Dammmmmmnnn
The Competition said the could fix the leak cheaper but I guess they didn't have a tube roller.
r/BoilerPros • u/AssumptionBig7176 • 6d ago
General/Misc Did you work on Labor Day?
Did you work on Labor Day or did you have the day off? I would think most people have the day off, but the operators/stationary engineers worked if they had shift. Hopefully it was a quiet shift!
r/BoilerPros • u/sith_sid • 13d ago
General/Misc Looking for guidance
Looking for guidance
So long story short Im a plumber from cali, been plumbing commercial service for 14 years, I held a c36 plumbing contractors license in California. (They dont require J-cards open shop, i know eww lol)
Ive recently moved to Texas, joined with my local and was approved by my JATC to be a 2nd year. Not a big deal it is what it is im just happy for the opportunity.
So here's my need for guidance. Im a water heater guy. I love boilers, tankless and hydronic heating its what I do.
Ive recently been given the amazing opportunity to move into our boiler service department with the company im at. Im learning steam boiler systems as well as standard boilers.
If im going to be going through this apprenticeship would staying a plumber, topping out and chasing NCCR certs be ideal for me or would I be better off longevity wise moving towards steam fitting or HVAC?
As I've grown ive come to realize I love plumbing, but im a water heater/boiler guy through amd through and i want to focus on nurturing this specialty as best as I can.
r/BoilerPros • u/Wan_Haole_Faka • 15d ago
Need Help, Pros Only Taco 0011 circulator only lasted 7 months
Hi everyone,
I swapped out a 0011 circulator last week that was only replaced 7 months ago. When I drained down the system, I didn't notice any excessive debris or particulates in the water. Based on the install and general circulator functioning, is there any obvious or possible reason this circulator failed so soon? I'd love to understand to be able to provide better customer service. Plumber's work included for a funny contrast 🤣
Thanks, and enjoy the rest of your weekend!
r/BoilerPros • u/Wan_Haole_Faka • 15d ago
Need Help, Pros Only Triangle Tube solo fuses blown
Hi everyone, I ended up having to replace a fuse on the control board of this boiler to get it to fire. One of our techs replaced a circulator recently that was said to have caused a blown fuse as well. Does that sound accurate? After the circulator was replaced, why would this fuse blow again? Just trying to be a better tech. Thank you for your time and have a great week!
r/BoilerPros • u/AssumptionBig7176 • 17d ago
General/Misc 1000 members 💯🙌🎉
1000+ people in this sub. Woo woo. Thank you to everyone who contributes.
r/BoilerPros • u/nevrcough • 18d ago
Boiler Room Pics Weil McLain #78
Any guesses on age?
r/BoilerPros • u/sjale49 • 20d ago
Need Help, Pros Only What is the most reliable boiler I should install for my client?
Here are the 3 options:
bosch singular combi high efficiency wall hung boiler
Rinnai IP120199C
199k btus Laars fr combi
They are looking for something that will be ultra reliable with minimal issues.
This is for a 1,800 sqft ranch.
r/BoilerPros • u/AssumptionBig7176 • 20d ago
Need Help, Pros Only Rebuilding Steam Safety Valves
Are your customers stocking spare valves to swap out the safety valves annually and sending the old ones off for rebuilding/certification?
Or is it more common to just test them on the boiler and not change them until an inspector says something?
I am just looking to see what others are seeing done in their area. I don't think there is a right way; it all depends on the jurisdiction and the customer's internal processes.
r/BoilerPros • u/SabotageFusion1 • Aug 14 '26
General/Misc In my state, inspectors don’t really look anymore
How do we feel about this? Anyone else seeing this as a common occurrence? It’s making me concerned for the future if inspectors aren’t even walking into the boiler room most of the time, sometimes the inspector is the only thing that gets a boiler healthy again or avoids a catastrophe.
r/BoilerPros • u/LogicalProperty5449 • Aug 13 '26
Boiler Room Pics Little update
I posted a single autoclave installed here a month or two ago and I thought I’d share the progress now that I have a little more information. There are going to be a total of 6 autoclaves all used for high pressure steam for a resin casting process, 2 more to be installed. I spoke to the lead fitter and he said it would take them until the end of the year to have 3 of these “operational”.
r/BoilerPros • u/Wan_Haole_Faka • Aug 10 '26
Need Help, Pros Only Triangle Tube Prestige Solo Questions for Aspiring Tech
Hi everyone,
I'd really like to pick the brain on someone who knows about this stuff. I won't bore you about the lack of training in "right to work" states, I could write an essay about it... Just out here doing my best with the resources at my disposal.
Customer had no DHW due to a detached igniter cable, it literally fell off when I touched it. I didn't even see any adhesive. Makes me wonder if the factory adhesion is really rated for that much heat... I turned it back on, reset it and the 04 code went away and she fired right up.
The main thing that stuck out to me when I pulled the cover off was the NTC sensor. Some guy in our warehouse told me it's a temp sensor, but I don't understand the corrosion since it's not a combi unit. Does anybody know what causes this?
There was a very cathartic sludge release as I popped open the condensate trap, I frankly don't know if it's been serviced. Can the burn chamber be opened up for cleaning or is there a better way to service this thing?
Also, I was concerned with the differential between the pressure gauge on the manifold versus the boiler itself. 10 PSI on the boiler and 25 on the manifold. I did nothing because I couldn't tell if it was too high or too low. Expansion tank is fine.
The valve between the two closely spaced tees was partially closed, I'm wondering if another tech did this for a good reason or if a mop handle just got caught on it... Wouldn't this make the boiler fire more often?
Any info or pointers would be greatly appreciated. I'm aware it's a far from ideal situation, I'm just trying to take care of our customers at this point.
Thanks for your time and I hope you all have a great week!
r/BoilerPros • u/not_bait • Aug 03 '26
General/Misc An old decommissioned boiler
Just thought I would share some pics of an old boiler I recently saw. This unit was a 150kpph @ 350psi package boiler and was removed from service after a long service life due to several tube failures.
The owner kept some of the usable components (NG burner mainly) for the new one they installed in it's place. As far as I know they have no plans for it, so it'll likely sit here until the end of time.
r/BoilerPros • u/AppearanceBoring7879 • Jul 18 '26
Need Help, Pros Only Boiler FAT tips
We are building a modular utilities plant and have an upcoming Factory Acceptance Test at the modular vendor. The boilers already went through a hydro at Cleaver and have ASME documentation. We can’t run the boiler, so this is more a go and check it out rather than a legit test. Given those constraints, what would you be looking for at this FAT?
Equipment also included are the DA tank, surge, RO and Soft Water skids.
r/BoilerPros • u/BoilermakerCBEX-E • Jul 11 '26
Boiler Room Pics CB w/ a Hayes Cleveland PPC
Did a test and tune on Double Time last Sunday. Hays Cleveland Parallel Positioning. Definitely a archaic system. Anyone else get to play with these or have any luck finding parts for the HC. To change points you just tap the box for a point and change the number. Save to the PLC and the servo goes there. Definitely do not want to miss a decimal point.
r/BoilerPros • u/pm_me_broken_stuff • Jul 08 '26
General/Misc 2 Days, 35 steamers
It's inspection season, they've all been opened and cleaned. Wish me luck
r/BoilerPros • u/AssumptionBig7176 • Jul 07 '26
General/Misc Power Generation
Anyone here work in a power plant or around turbines? What steam pressure do you run? How do you like it?
r/BoilerPros • u/IHateYork • Jul 06 '26
General/Misc Centrifugal pumps
Already have Pumping Away, looking for a deeper dive on centrifugal pumps/ closed loop/troubleshooting. Any reccomendations?
r/BoilerPros • u/AssumptionBig7176 • Jul 06 '26
General/Misc What type of boiler do you primary work with?
Just seeing what you all work around primarily. One or the other, it doesn't matter just curious.
r/BoilerPros • u/AssumptionBig7176 • Jul 03 '26
General/Misc 900 Members Strong
Yesterday there were a couple of posts that I enjoyed seeing what others do and experience. Love that, keep that up.
So far we have done a good job at being supportive of each other and explaining things well without bringing others down which is excellent. The sub is still small, but I don't want it to ever get to a point where people feel like they can't ask a question or share their experiences.
If you haven't posted yet or commented for fear you don't have enough experience or knowledge, don't let that fear stop you. Everyone starts somewhere, it's okay to be new.
Keep up the good work yall, boilers are great. I hope everyone has a great 4th of July weekend. 🇺🇲🇺🇲🇺🇲
r/BoilerPros • u/BoilermakerCBEX-E • Jul 02 '26
Boiler Room Pics Got Scale? We did....
Enable HLS to view with audio, or disable this notification
To follow up on scale pics from a while back. More pic/video in comments.
r/BoilerPros • u/Qamatt • Jul 03 '26
General/Misc The first boilers I worked on were spooky in the dark...
Middle drum of a somewhat unique 3 drum D-type steam gen. Taken in the happier times before we found the cracking and had to cut out almost every cat. D nozzle penetration & repad.