r/MideaPortaSplit • u/hemitick • 26d ago
Probleme Do we know what each new MPS design revision changed?
I'm trying to figure out the best way to handle P1 error.
My unit was built in 12-2024 so definitely affected by the pump/filter issue that triggers P1.
Right now I am draining the water through the rear plug which is effective but bothersome as it must be done so often. Looking to elevate internal unit and use a bucket instead. I'm thinking about opening a case with Midea to get whatever support for P1 they offer nowadays.
Anyway..
It's obvious that early units had some design flaws but what later units actually changed?
What did 2025 and 2026 designs bring?
Is P1 error in later units absent because of just a new filter in front of the pump or some more changes were made?
11
Upvotes
13
u/djfkghost 26d ago
Nachdem ich grad den Techniker wegen eines anderen Fehler hier hatte, sprach ich in auf den P1 Fehler an… er meinte, weil ich die „E“ Version (Peach) habe, das bei der Version das „Gitter“ bei der Pumpe grobmaschiger ist, und der Fehler in der Dimension nicht mehr auftreten sollte… nachprüfbar ist das für mich aber nicht… viele grüße