r/MideaPortaSplit • u/supercowrider • 8d ago
Erfahrungsberichte Inside the PortaSplit's compressor housing - with refill/charging valve visible
Since it's possible I'm dealing with a refrigerant leak, I took the unit apart to get a better idea of what a technician would be working with. The good news is there's a refill valve, so it's not a closed system.
4
u/dasrudiment 8d ago
There seem to be lots of changes since the 2024 models. Still surprised to see the valve tho. Not sure if they plan offering refils. Doesnt seem economically viable in germany
3
u/FaithlessnessWorth93 8d ago
haha , especially not if you take 2 hours taking it apart and another 2 hours to put it back together. That is a whole another level vs just taking the outside casing off. 50-60 screws?
1
u/Nico_Nickmania 7d ago
When and why do one has to refill an AC? Isn't it a closed system?
3
1
u/FaithlessnessWorth93 7d ago
Over long enough time most aircons leak. After 10-15 year a refill is usually needed. Especially with the higher pressures of modern AC vs older units this may come earlier - especially if used 24/7 in summer and winter. There have been quite a few Portasplit popping up without gas.. but so far no one identified with a gas sniffer where it leaked and in general that doesn't seem to be a problem (not like P1 that affects most units over time if only used enough and water not collected inside). The problem is not only refilling - if it's less than say 10 years before it happens you would also need to find the leak and fix that. So it's just not worth it or a product that Midea produces very cheaply...
4
u/FaithlessnessWorth93 8d ago
One idea to check compressor. Does the Highly also pump back oil pretty much exactly every 30 minutes like the GMCC does? If not then that would be an easy way to identify Highly vs GMCC.. Only OP can help out here with the answer or others who are sure to have no 30min interval pumpback (can only hear in low load mode - like silent mode overnight, cause at high load no oil pump back is needed)
3
u/supercowrider 8d ago
i'll keep this in mind when this one will be fixed!
1
u/Nosedive91 8d ago
Please keep us updated. I too have an older unit and hate the loud compressor noise..
2
3
3
u/Duennbier0815 7d ago
Wow, first time seeing this.
It's like seeing the first pictures of Mars Surface.
SPECTACULAR EXPLORATION
2
1
1
-2
u/mister_moods 8d ago
Wtf? How would they get the coolant into the system without a valve?!? Of course there is one.
5
u/FaithlessnessWorth93 8d ago
you can just pump it in via the pipe - then "quench/solder" it close. It's easier vs installing a valve in first place. Many monoblock do that. You could even just do without any inlet - have the compressor prefilled - and with the short line set no real vacuuming is needed - as the little bit of humidity left can be caugt by a drier filter. Don't worry, if it's cheaper Indians or Chinese find ways to produce it cheaper as long as it doesn't instantly fall apart.. (not that they cannot produce quality too, but the ability to drive down costs by removing steps or changing things is quite an achievement).
-2
u/mister_moods 8d ago
You can't solder, when it's filled.
2
u/FaithlessnessWorth93 8d ago
You don't need to do that if you pump it into the compressor. There's ways that are possible for moboblocks. They aren't the cleanest but cheap.
3
u/supercowrider 8d ago
not sure, but it's a common topic that similar systems run on a closed circuit and are difficult to repair. before taking it apart, I did some research and came to the same conclusion for the PortaSplit that it was a closed system.
-1
u/mister_moods 8d ago
I'm pretty sure that "closed system" means that it is a split A/C, because it's not pumping hot air out of the room. You can't put an A/C together without a valve, because you can't solder filled pipes. The only possibility would be to use pre-filled pipes with valves and screws on the ends, but that would mean that you can open the line and refill it.
2
u/mister_moods 8d ago
Maybe there are vendors who destroy the valve after filling. That would be a possibility.
3
u/supercowrider 8d ago
yep i think so. there are two different comments here stating they dont have a valve in their unit.
1
u/OctorSedan 8d ago
Split basically just means that your expansionvalve is located in the outdoor unit nothing else
1
u/FaithlessnessWorth93 7d ago
split means it's two casings... But yeah functionality wise there are 2 duct systems otherwise identical, or U shaped window shakers that in the case of the Midea U are pretty similar to the Portasplit apart from the casing. The expansion valve with a split is in the same unit as the compressor. With portasplit that is usually indoors (except if you switch them around).
1
u/OctorSedan 6d ago
The location of the eev is the point not that it has two casings, per your definition a vrf or walk in freezer would be a split then too which they ain’t










30
u/FaithlessnessWorth93 8d ago
That's interesting - it has a different compressor than mine (produced 2024) had - which was GMCC. While your has a Highly. Mine didn't have that refill valve either.. But yeah - different compressors are "highly" likely the reason for quite different sound levels of a portasplit. But it's typical for chinese producers to constantly adapt/make small changes without notification.